Summary for Test 2024-10-03-89-4
Test performed: ASTM D2628-91r16Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/03/2024 | Sample Unique Key | 89 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/15/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 2.5" Joint Seal | The quantity of what the sample constitutes | 600' |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Simon | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | D.S. Brown | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0724361 |
|---|---|---|---|
| Manufacturer(s) | DS Brown | Temperature | 72 |
| Humidity | 50 | Comments | |
| Joint Seal Size | 2.5 |
Test Details
DIME Sample ID: 2024-10-03-89
DIME Test ID: 2024-10-03-89-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2628-91r16: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements
Test Release Date: 2024-12-05
Test Results
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 12/05/2024
High or low tempurature: High
Temperature: 72 f
Humidity: 50 %
Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face ): 2.609 in
Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face ): 2.368 in
Percent Recovery: 91 %
General comments (publicly viewable) (Max 1000 characters): hot
Test was verified on 12/5/2024 ✔