Summary for Test 2024-10-30-57-9
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1000188 DEA: 112N1694 EFIS: 1122000282 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-78-3.3/72.9 |
| Award Date | 05/30/2024 |
| Closeout Date | 06/09/2025 |
| Work Description | GRIND BRIDGE DECK, PLACE POLYESTER CONCRETE, AND APPLY METHACRYLATE. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM COLLEGE BOULEVARD UNDERCROSSING TO SAN FELIPE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 06/11/2024) |
Sample Information
| Sample Taken Date | 10/30/2024 | Sample Unique Key | 57 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/18/2024 | Sample type | Acceptance |
| A brief description of the sample | PSU Aggs | The quantity of what the sample constitutes | 4 bags |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Derrick |
| Last name of sampler or witnessed by | McCovy | Title of sampler | |
| Telephone number of sampler | 6192463546 | Laboratory sample identification | 1301-PSU |
| Linked DIME Sample ID | 2024-10-30-56 | The fabricator/manufacturer/facility name | Vulcan CC |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Provided |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Aggregates | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 320819 CC SJR |
Test Details
DIME Sample ID: 2024-10-30-57
DIME Test ID: 2024-10-30-57-9
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-12-16
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 12/04/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7475.6 grams
Mass of oven-dry sample in air for Sample 1: 1550 grams
Mass of container filled with the sample and water for Sample 1: 8393.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.451
Theoretical maximum density at 25°C (77°F): 152.6 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): RAP Rice
Test was verified on 12/16/2024 ✔