Summary for Test 2024-09-27-86-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994869
DEA: 073237U4
EFIS: 0720000224
DIST-CO-RTE-PM07-VEN-150-13.3/19
Award Date03/27/2023
Closeout Date07/15/2026
Work DescriptionPLACE HMA (TYPE A) AND COLD PLANE ASPHALT
Location DescriptionVENTURA COUNTY IN AND NEAR OJAI FROM BURNHAM ROAD TO GORHAM ROAD
QA Service Level1 (Verified on 06/26/2023)

Sample Information

Sample Taken Date09/27/2024 Sample Unique Key86
Date that the sample was received by the laboratory/organization performing the testing10/01/2024 Sample typeAcceptance
A brief description of the sample3/4" HMA-A 220200 SAT LTR The quantity of what the sample constitutes750 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byChris
Last name of sampler or witnessed byFurtado Title of samplerVulcan QC
Telephone number of sampler Laboratory sample identification24-295
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials Saticoy
Transportation Laboratory (TL) Number092724A Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220200 SAT LTR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-27-86
DIME Test ID: 2024-09-27-86-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-04

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 10/15/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4033.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 6048.6 g
Mass of HMA Sample prior to ignition: 2015.4 g
Mass Loss: 106.0 g
Mass of aggregate remaining after ignition: 1909.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.06 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.20 %
General comments (publicly viewable) (Max 1000 characters):