Summary for Test 2024-11-27-8-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000018 DEA: 042Q7604 EFIS: 0419000046 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-238,680-0.7/0.8,M0.1 |
| Award Date | 05/22/2024 |
| Closeout Date | Not set |
| Work Description | RECTANGULAR RAPID FLASHING BEACON SYSTEMS, HMA, CURB RAMP AND SW. |
| Location Description | ALAMEDA COUNTY IN FREMONT ON ROUTE 680 AT OFF-RAMP TO SCOTT CREEK ROAD AND ON ROUTE 238 AT MISSION BRIDGE COURT |
| QA Service Level | 1 (Verified on 01/08/2024) |
Sample Information
| Sample Taken Date | 11/27/2024 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/28/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4-inch HMA Type A |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Source |
| First name of sampler or witnessed by | Abeer | Last name of sampler or witnessed by | Dahhan |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | De Silva Gates - Sunol | Transportation Laboratory (TL) Number | C112724 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | MD 6742 WM |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-11-27-8
DIME Test ID: 2024-11-27-8-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-04
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Rob Lohman
Date of test: 11/27/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3552.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 5570.7 g
Mass of HMA Sample prior to ignition: 2018.2 g
Mass Loss: 128.7 g
Mass of aggregate remaining after ignition: 1889.5 g
Correction Factor (Percent by mass of HMA Specimen): 1.23 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.10 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.05 %
General comments (publicly viewable) (Max 1000 characters): Burn #1
Test was verified on 12/4/2024 ✔