Summary for Test 2024-10-09-44-4

Test performed: ASTM D7741-11ε1

Project Information

Project IdentifiersProject ID: 994574
DEA: 050C7334
EFIS: 0518000116
DIST-CO-RTE-PM05-SCR-1-10.5/13.4
Award Date06/29/2023
Closeout DateNot set
Work DescriptionCONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/13/2023)

Sample Information

Sample Taken Date10/09/2024 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing10/15/2024
Sample typeAcceptance A brief description of the sample 1 qt Can of ARB
The quantity of what the sample constitutes10/09/24 From where was the sample collectedSource
First name of sampler or witnessed byAndy Last name of sampler or witnessed byCecena
Title of samplerQC Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite ARB Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number1
Sublot number4 Asphalt Rubber Binder Mix Number23_1696

Test Details

DIME Sample ID: 2024-10-09-44
DIME Test ID: 2024-10-09-44-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D7741-11ε1: Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Handheld Viscometer (Viscosity)
Test Release Date: 2024-12-03

Test Results


Unit system used?: SI Units
Input Type: Measured
Tester's full name: field tech
Date of test: 12/03/2024
Test Temperature: 190 C
Test 1 Viscosity: 1900.0 Pa-s
Test 2 Viscosity: 1900.0 Pa-s
Test 3 Viscosity: 1900.0 Pa-s
Average Viscosity: 1900.0
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): VISCOSITY

Test was verified on 12/3/2024