Summary for Test 2024-11-01-63-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 214135
DEA: 09213404
EFIS: 0900000030
DIST-CO-RTE-PM09-INY-395-29.9/41.8
Award Date10/22/2021
Closeout Date05/29/2026
Work DescriptionROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location DescriptionINYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
QA Service Level1 (Verified on 05/03/2019)

Sample Information

Sample Taken Date11/01/2024 Sample Unique Key63
Date that the sample was received by the laboratory/organization performing the testing11/04/2024 Sample typeQuality Assurance
A brief description of the sample4x8 concrete cylinders The quantity of what the sample constitutes250 cy
From where was the sample collectedJob Site First name of sampler or witnessed byJerid
Last name of sampler or witnessed byKupelian Title of samplerConsultant
Telephone number of sampler Laboratory sample identificationPCC-101
Linked DIME Sample ID The fabricator/manufacturer/facility name7-11 Materials Bishop
Transportation Laboratory (TL) Number4500 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameDS 1114
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number00-00-0000
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedMiddle of 1st Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-01-63
DIME Test ID: 2024-11-01-63-3
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-12-03

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 12/02/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 51600 lb
Maximum load on cylinder 2: 52740 lb
Maximum load on cylinder 3: 53590 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 31 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4105.0 psi
Compressive strength of cylinder 2: 4195.7 psi
Compressive strength of cylinder 3: 4263.3 psi
Compressive strength (to nearest 10 psi): 4190 psi
General comments (publicly viewable) (Max 1000 characters): DS 1114 NL Inlet Headwall

Test was verified on 12/3/2024 ✔