Summary for Test 2024-09-13-81-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994869 DEA: 073237U4 EFIS: 0720000224 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-150-13.3/19 |
| Award Date | 03/27/2023 |
| Closeout Date | Not set |
| Work Description | PLACE HMA (TYPE A) AND COLD PLANE ASPHALT |
| Location Description | VENTURA COUNTY IN AND NEAR OJAI FROM BURNHAM ROAD TO GORHAM ROAD |
| QA Service Level | 1 (Verified on 06/26/2023) |
Sample Information
| Sample Taken Date | 09/13/2024 | Sample Unique Key | 81 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/18/2024 |
| Sample type | Acceptance | A brief description of the sample | 3/4" HMA-A 220200 SAT LTR |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Furtado |
| Title of sampler | Vulcan QC | Telephone number of sampler | |
| Laboratory sample identification | 24-243 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Materials Saticoy | Transportation Laboratory (TL) Number | 091324E |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220200 SAT LTR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-09-13-81
DIME Test ID: 2024-09-13-81-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-02
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 09/19/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4026.4 g
Mass of the specimen and specimen basket assembly prior to ignition: 6075.5 g
Mass of HMA Sample prior to ignition: 2049.1 g
Mass Loss: 100.7 g
Mass of aggregate remaining after ignition: 1948.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.91 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/2/2024 ✔