Summary for Test 2024-11-14-49-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000580
DEA: 071XW104
EFIS: 0723000028
DIST-CO-RTE-PM07---
Award DateNot set
Closeout DateNot set
Work DescriptionVENTURA COUNTY IN CITY OF FILLMORE VEN-126REPLACE/CONSTRUCT THE FILLMORE MAINTENANCESTATION DAMAGED BY HIGH WINDS DIR\\'S EMERGENCY
Location DescriptionNot set
QA Service Level1 (Verified on 09/09/2024)

Sample Information

Sample Taken Date11/14/2024 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/19/2024
Sample typeInformational A brief description of the sample4X8 PCC cylinders
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byAziz Last name of sampler or witnessed byMAGHSOUDLOO
Title of samplerStructure Representative Telephone number of sampler
Laboratory sample identification24-406 Linked DIME Sample ID
The fabricator/manufacturer/facility nameState Ready Mix Transportation Laboratory (TL) Number11142024
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number150156
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected90166
Concrete batch plantState Ready Mix The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-14-49
DIME Test ID: 2024-11-14-49-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-12-02

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 11/28/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 60539 lb
Type of fracture pattern of cylinder 1: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 14 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Compressive strength of cylinder (to nearest 10 psi): 4820 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/2/2024