Summary for Test 2024-11-06-67-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 995085 DEA: 07322904 EFIS: 0716000059 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-27-0.0/18.6 |
| Award Date | 11/06/2023 |
| Closeout Date | Not set |
| Work Description | REMOVE EXISTING AC PAVEMENT & HMA OVERLAY. |
| Location Description | LOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET |
| QA Service Level | 1 (Verified on 09/11/2023) |
Sample Information
| Sample Taken Date | 11/06/2024 | Sample Unique Key | 67 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/06/2024 |
| Sample type | Acceptance | A brief description of the sample | C-70, Costanso St and CA-27 |
| The quantity of what the sample constitutes | 45 sy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Caesar | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Transportation Engineer Civil | Telephone number of sampler | (818) 974-8391 |
| Laboratory sample identification | 24-3434 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Contractor | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | C-70, Costanso St and CA-27 | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Subgrade |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Job site | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-11-06-67
DIME Test ID: 2024-11-06-67-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-12-02
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Caesar Ramirez
Date of test: 11/06/2024
Gage No.: 31106
Test No.: 1
Nuclear By: Caesar Ramirez
Non-Bias Plan No.: NA
Depth: 5"
Material No.: Native
Material Type: Subgrade
Impact By: Caesar Ramirez
Standard Count Density: 2156 g/cc
Count or Density 1: 1.54 g/cc
Count or Density 2: 1.52 g/cc
Count or Density 3: 1.53 g/cc
Standard Count Moisture: 630 g/cc
Moisture Count 1: 0.13 g/cc
Moisture Count 2: 0.13 g/cc
Moisture Count 3: 0.14 g/cc
Sum of Count or Density: 4.59 g/cc
Average of Count or Density: 1.53 g/cc
Sum of Moisture Count: 0.4 g/cc
Average of Moisture Count: 0.13 g/cc
Calculated Percent Relative Compaction: 72.9 %
Reported Percent Relative Compaction: 73 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/2/2024 ✔