Summary for Test 2024-11-18-24-5
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 993184 DEA: 040A7724 EFIS: 0420000288 COOP: 0422825 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-80-6.4/6.8 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Excavation, HMA, structural concrete, minor concrete and drainage. |
| Location Description | IN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 11/18/2024 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/19/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA Type A |
| The quantity of what the sample constitutes | 4 boxes 75 Tons out | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jose Leon | Last name of sampler or witnessed by | Amparan |
| Title of sampler | QA LabTechnician | Telephone number of sampler | 8317060175 |
| Laboratory sample identification | Linked DIME Sample ID | 2024-11-18-35 | |
| The fabricator/manufacturer/facility name | Dutra Richmond | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 9 |
| Sublot number | 1 | HMA Mix Number | L240097 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-11-18-24
DIME Test ID: 2024-11-18-24-5
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-12-19
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Jose Leon Amparan
Date of test: 11/20/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4557.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 5981.9 g
Mass of HMA Sample prior to ignition: 1424.7 g
Mass Loss: 130.2 g
Mass of aggregate remaining after ignition: 1294.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.24 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.90 %
General comments (publicly viewable) (Max 1000 characters): RAP
Test was verified on 12/19/2024 ✔