Summary for Test 2024-11-02-8-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 995193
DEA: 07356604
EFIS: 0719000026
DIST-CO-RTE-PM07-LA-605-R10.2/20.2
Award Date04/04/2024
Closeout DateNot set
Work DescriptionLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
QA Service Level1 (Verified on 10/03/2023)

Sample Information

Sample Taken Date11/02/2024 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing11/02/2024 Sample typeAcceptance
A brief description of the sampleLane #2 on the SB 605 The quantity of what the sample constitutes120 CY
From where was the sample collectedJob Site First name of sampler or witnessed byCaesar
Last name of sampler or witnessed byRamirez Title of samplerTransportation Engineer Civil
Telephone number of sampler(818) 974-8391 Laboratory sample identification24-3399
Linked DIME Sample ID The fabricator/manufacturer/facility nameContractor
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameLane #2 on the SB 605
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberVCTS675
The truck number from where the sample was collected3 The batch plant ticket number from where the sample was collected3
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJob site Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-02-8
DIME Test ID: 2024-11-02-8-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-11-26

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Caesar Ramirez
Date of test: 11/05/2024
Identification number: 07-3399
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8108 lb
Maximum load applied 2: 7821 lb
Maximum load applied 3: 8401 lb
Curing history and apparent moisture condition of the specimen: 3 Days
If specimen was capped, ground or if leather shims were used: NA
Defects in specimen, including numbers of beams discarded during test: NA
Age of specimen: 3 days
Age of specimen in hours: 72 hours
Modulus of rupture: 710 psi
Modulus of rupture 2: 680 psi
Modulus of rupture 3: 740 psi
Modulus of rupture average: 710 psi
General comments (publicly viewable) (Max 1000 characters): 430 psi after 60 minutes reported to inspector Alexander Dagher

Test was verified on 11/26/2024 ✔