Summary for Test 2024-11-19-33-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000286
DEA: 070W7004
EFIS: 0723000032
DIST-CO-RTE-PM07-LA-405-44.7/48.64
Award Date06/19/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), & GRIND EXIST CONC PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM NORDHOFF STREET UNDERCROSSING TO ROUTE 5/405 SEPARATION
QA Service Level1 (Verified on 09/16/2024)

Sample Information

Sample Taken Date11/19/2024 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/19/2024
Sample typeAcceptance A brief description of the sampleRoute 405 NB
The quantity of what the sample constitutes200 cy From where was the sample collectedJob Site
First name of sampler or witnessed byCaesar Last name of sampler or witnessed byRamirez
Title of samplerTransportation Engineer Civil Telephone number of sampler(818) 974-8391
Laboratory sample identification24-3588 Linked DIME Sample ID
The fabricator/manufacturer/facility nameContractor Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameRoute 405 NB Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collectedShort Load Concrete
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJob site Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-19-33
DIME Test ID: 2024-11-19-33-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-11-26

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Stress
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Caesar Ramirez
Date of test: 11/22/2024
Identification number: 07-3588
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum recording: 825 psi
Maximum recording 2: 925 psi
Maximum recording 3: 910 psi
Curing history and apparent moisture condition of the specimen: 3 Days
If specimen was capped, ground or if leather shims were used: NA
Defects in specimen, including numbers of beams discarded during test: NA
Age of specimen: 3 days
Age of specimen in hours: 72 hours
Modulus of rupture: 870 psi
Modulus of rupture 2: 970 psi
Modulus of rupture 3: 960 psi
Modulus of rupture average: 930 psi
General comments (publicly viewable) (Max 1000 characters): 460 psi at 90 minutes reported to inspector Wudnich Wodtensay

Test was verified on 11/26/2024