Summary for Test 2024-11-14-44-1
Test performed: ASTM A970-18Project Information
| Project Identifiers | Project ID: 994326 DEA: 051C3604 EFIS: 0512000134 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-217-0.9/1.4 |
| Award Date | 01/31/2023 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 10/17/2022) |
Sample Information
| Sample Taken Date | 11/14/2024 | Sample Unique Key | 44 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/20/2024 | Sample type | Quality Assurance |
| A brief description of the sample | #9 HRC 150 T-Heads | The quantity of what the sample constitutes | 8 of 900 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Lorenzo |
| Last name of sampler or witnessed by | Garcia | Title of sampler | Quality Assurance Inspector |
| Telephone number of sampler | 7029172503 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Headed Reinforcement Corp, Fountain Valley, CA | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-160-24 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 223022 | Head Manufacturer Lot Number(s) | 400002289021 |
| Rebar Size | #9 | Headed Bar Model Name | HRC 150 THeads |
| Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
| Head Shape | Circular | Rebar Manufacturer | Cascade Steel |
| Head Manufacturer | Nucor | Head Fabricator | Nucor |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Test Details
DIME Sample ID: 2024-11-14-44
DIME Test ID: 2024-11-14-44-1
Testing Lab: Kleinfelder, Incorporated - Sacramento
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2024-11-25
Test Results
Number of Headed Bar Samples: 4
Input Type: Calculated
Tester's full name: Michael Kalwasinski
Date of test: 11/25/2024
UTM: NA
Temperature: 72 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 100930 | 101000 | na | MK |
| 2 | 1 | 1 | 100870 | 101000 | na | MK |
| 3 | 1 | 1 | 102500 | 103000 | na | MK |
| 4 | 1 | 1 | 99360 | 99500 | na | MK |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/25/2024 ✔