Summary for Test 2024-11-13-66-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994326 DEA: 051C3604 EFIS: 0512000134 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-217-0.9/1.4 |
| Award Date | 01/31/2023 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 10/17/2022) |
Sample Information
| Sample Taken Date | 11/13/2024 | Sample Unique Key | 66 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/20/2024 |
| Sample type | Quality Assurance | A brief description of the sample | HRC 500/510 coupler Lot 1 and Lot 4 |
| The quantity of what the sample constitutes | 600 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 915 296 1869 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Integrity Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-058-24 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Cascade |
| Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Integrity Rebar Placers |
| Rebar Size | #9 | Coupler Model | HRC 500/510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | HRC500 A224297 HRC510 A232690 | Rebar Heat Number(s) | 388922 |
| Rebar Size 2 | 9 | Coupler Unique ID | TP-17-03 |
Test Details
DIME Sample ID: 2024-11-13-66
DIME Test ID: 2024-11-13-66-2
Testing Lab: Kleinfelder, Incorporated -Sacramento
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2024-11-25
Test Results
Number of Samples: 4
Input Type: Calculated
Tester's full name: Michael Kalwasinski
Date of test: 11/25/2024
UTM: NA
Halo ID: na
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 4 | 9 | 1 | 0.012 | 102190 | 102000 | na | MK |
| 2 | 2 | 4 | 9 | 1 | 0 | 103360 | 103000 | na | MK |
| 3 | 3 | 4 | 9 | 1 | 0 | 102870 | 103000 | na | MK |
| 4 | 4 | 4 | 9 | 1 | 0 | 102760 | 103000 | na | MK |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/25/2024 ✔