Summary for Test 2017-08-28-4-2

Test performed: ASTM A884-13

Project Information

Project IdentifiersProject ID: 211394
DEA: 100G8204
EFIS: 1013000073
DIST-CO-RTE-PM10-SJ-132-0.4/7.1
Award Date07/20/2016
Closeout Date01/04/2021
Work DescriptionREPAIR PAVEMENT AND INSTALL ITS ELEMENTS.
Location DescriptionSAN JOAQUIN COUNTY NEAR VERNALIS FROM 0.4 MILE EAST OF ROUTE 580 TO STANISLAUS COUNTY LINE
QA Service Level1 (Verified on 09/23/2016)

Sample Information

Sample Taken Date08/28/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/29/2017
Sample typeQuality Assurance A brief description of the sampleEpoxy Coated Dowel Basket
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byEd Last name of sampler or witnessed byLeach
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDayton Superior Transportation Laboratory (TL) NumberC925886
Inspector Lot Number from the Transportation Laboratory (TL) FormS3811417 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat NumberNa
Dowel Epoxy Batch NumberUnknown Dowel Coating SpecificationASTM A884
Dowel Size1.25 in Dowel Coating ColorGreen
Dowel ManufacturerDayton Superior Dowel CoaterDayton Superior
Release Number1349571-2 Quality Assurance CodeUnknown
Rebar Size (#)Unknown

Test Details

DIME Sample ID: 2017-08-28-4
DIME Test ID: 2017-08-28-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Test Release Date: 2017-09-07

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 08/31/2017
Total Number of Holiday: 0
Total Length: 3 ft
Holidays Per Linear Foot of Bar: 0 holiday per ft
Holiday Test Pass/Fail: Pass
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/31/2017