Summary for Test 2024-11-21-26-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000286
DEA: 070W7004
EFIS: 0723000032
DIST-CO-RTE-PM07-LA-405-44.7/48.64
Award Date06/19/2024
Closeout Date12/24/2025
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), & GRIND EXIST CONC PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM NORDHOFF STREET UNDERCROSSING TO ROUTE 5/405 SEPARATION
QA Service Level1 (Verified on 09/16/2024)

Sample Information

Sample Taken Date11/21/2024 Sample Unique Key26
Date that the sample was received by the laboratory/organization performing the testing11/24/2024 Sample typeAcceptance
A brief description of the sampleJPCPRS Beams The quantity of what the sample constitutes10CY
From where was the sample collectedJob Site First name of sampler or witnessed byChad
Last name of sampler or witnessed byChotibhongs Title of samplerMREA
Telephone number of sampler2134076963 Laboratory sample identification24-3628
Linked DIME Sample ID The fabricator/manufacturer/facility nameG3
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedfrom short-load truck on-site Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-11-21-26
DIME Test ID: 2024-11-21-26-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-11-25

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Chad Chotibhongs
Date of test: 11/25/2024
Identification number: 24-3628
Width of specimen: 6.0625 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 11338 lb
Maximum load applied 2: 10974 lb
Maximum load applied 3: 11635 lb
Curing history and apparent moisture condition of the specimen: 3days
If specimen was capped, ground or if leather shims were used: NA
Defects in specimen, including numbers of beams discarded during test: 0
Age of specimen: 3 days
Age of specimen in hours: 0 hours
Modulus of rupture: 980 psi
Modulus of rupture 2: 960 psi
Modulus of rupture 3: 1000 psi
Modulus of rupture average: 980 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/25/2024 ✔