Summary for Test 2024-10-11-88-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994864
DEA: 050N74U4
EFIS: 0522000025
DIST-CO-RTE-PM05-SB-101-9.9/10.6
Award Date07/10/2023
Closeout DateNot set
Work DescriptionSB 101 4D North San Ysidro to Olive Mill
Location DescriptionIn Santa Barbara County in and near Santa Barbara from 0.1 mile south of San Ysidro Road Overcrossing to 0.1 north of Olive Mill Road Overcrossing
QA Service Level1 (Verified on 08/21/2023)

Sample Information

Sample Taken Date10/11/2024 Sample Unique Key88
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/12/2024
Sample typeQuality Control A brief description of the samplestructural concrete
The quantity of what the sample constitutes2 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byHarrison Last name of sampler or witnessed byKain
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Santa Barbara Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1629003
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected31377425
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedRW 122 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-11-88
DIME Test ID: 2024-10-11-88-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-11-22

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jorge reyes
Date of test: 11/08/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 161790 lb
Maximum load on cylinder 2: 156350 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5630 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/22/2024