Summary for Test 2024-11-18-24-4

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 993184
DEA: 040A7724
EFIS: 0420000288
COOP: 0422825
DIST-CO-RTE-PM04-ALA-80-6.4/6.8
Award DateNot set
Closeout DateNot set
Work DescriptionExcavation, HMA, structural concrete, minor concrete and drainage.
Location DescriptionIN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date11/18/2024 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/19/2024
Sample typeQuality Assurance A brief description of the sample3/4 HMA Type A
The quantity of what the sample constitutes4 boxes 75 Tons out From where was the sample collectedSource
First name of sampler or witnessed byJose Leon Last name of sampler or witnessed byAmparan
Title of samplerQA LabTechnician Telephone number of sampler8317060175
Laboratory sample identification Linked DIME Sample ID2024-11-18-35
The fabricator/manufacturer/facility nameDutra Richmond Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number9
Sublot number1 HMA Mix NumberL240097
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-11-18-24
DIME Test ID: 2024-11-18-24-4
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2024-12-19

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Jose Leon Amparan
Date of test: 11/19/2024
Cumulative Mass RetainedCumulative Percent Passing
1328.0 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
3.2 grams100 %
198.9 grams85 %
460.5 grams65 %
680.3 grams49 %
843.7 grams36 %
995.8 grams25 %
1135.8 grams14 %
1204.8 grams9.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/19/2024