Summary for Test 2024-11-21-12-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215425
DEA: 06360244
EFIS: 0613000005
DIST-CO-RTE-PM06-TUL-99-30.6/35.2
Award Date04/23/2021
Closeout DateNot set
Work DescriptionWiden Freeway & Bridge Construction (Concrete Bridge)
Location DescriptionNot set
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date11/21/2024 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/21/2024
Sample typeQuality Assurance A brief description of the sample3/4 HMA-A PG70-10
The quantity of what the sample constitutesL8SL80 From where was the sample collectedSupplier
First name of sampler or witnessed byMartika Last name of sampler or witnessed byHall
Title of samplerJET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Mariatta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameNB TUL 99 N of Ave 264 Tagus Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number8
Sublot number80 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-11-21-12
DIME Test ID: 2024-11-21-12-1
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-11-21

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Chris Elias
Date of test: 11/21/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2061.7 g
Mass Loss: 107.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.15 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.60 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.48 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/21/2024