Summary for Test 2024-11-21-11-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Sample Information

Sample Taken Date11/21/2024 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/21/2024
Sample typeAcceptance A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes50 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byHonesto Last name of sampler or witnessed byCastillo
Title of samplerMREAS Telephone number of sampler2134537563
Laboratory sample identification0057C Linked DIME Sample ID2024-11-21-9 & 2024-11-21-10
The fabricator/manufacturer/facility nameROBERTSONS POMONA Transportation Laboratory (TL) NumberC 003434
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0072
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number5 A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design numberSC675B38 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-11-21-11
DIME Test ID: 2024-11-21-11-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-11-25

Test Results


Number of tests: 2
Input Type: Measured
Tester's full name: Honesto Castillo
Date of test: 11/21/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.5
Sand reading (test 1): 3.9
Clay reading (test 2): 4.5
Sand reading (test 2): 3.7
Sand equivalent (test 1): 87
Sand equivalent (test 2): 83
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/25/2024