Summary for Test 2024-10-08-115-5
Test performed: AASHTO T84-14Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/08/2024 | Sample Unique Key | 115 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/08/2024 |
Sample type | Verification | A brief description of the sample | JMF |
The quantity of what the sample constitutes | 9 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 7001-JMF | Linked DIME Sample ID | 2024-10-08-114 |
The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Provided |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plnat | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | 23417105 MM |
Test Details
DIME Sample ID: 2024-10-08-115
DIME Test ID: 2024-10-08-115-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2024-11-25
Test Results
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 11/19/2024
Mass of saturated surface dry sample (before pycnometer) (S): 501.5 grams
Mass of the pycnometer with water and aggregate (C): 989.7 grams
Mass of the pycnometer with water (B): 680.3 grams
Mass of the oven dried sample (before pycnometer) (A): 491 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 501.5 grams
Mass of the oven dry aggregate (for absorption) (A): 491 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.556
Bulk specific gravity (SSD Basis): 2.611
Apparent specific gravity: 2.704
Absorption: 2.1 %
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 11/25/2024 ✔