Summary for Test 2024-11-16-2-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 212720 DEA: 07291404 EFIS: 0712000094 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-1-55-58 |
| Award Date | 02/18/2021 |
| Closeout Date | 04/23/2026 |
| Work Description | TRANCAS CREEK BRIDGE REPLACEMENT |
| Location Description | IN LOS ANGELES IN CITY OF MALIBU AT TRANCAS CREEK BRIDGE (53-0027). |
| QA Service Level | 1 (Verified on 04/02/2021) |
Sample Information
| Sample Taken Date | 11/16/2024 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/16/2024 | Sample type | Acceptance |
| A brief description of the sample | WCS PCC Aggregate | The quantity of what the sample constitutes | 20 CY |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Hopkins | Title of sampler | Plant Inspector |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Associated Ready Mix - Oxnard | |
| Transportation Laboratory (TL) Number | C111624C | Inspector Lot Number from the Transportation Laboratory (TL) Form | KH107G |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0054 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | Associated RM Oxnard | A detailed description of where the material sample was collected | Conveyor Belt |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | SL675350SP | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-11-16-2
DIME Test ID: 2024-11-16-2-2
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-11-25
Test Results
Number of tests: 2
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 11/18/2024
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 45
Sand reading (test 1): 38
Clay reading (test 2): 44
Sand reading (test 2): 37
Sand equivalent (test 1): 85
Sand equivalent (test 2): 85
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/25/2024 ✔