Summary for Test 2024-10-30-47-2

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 1000299
DEA: 042Y4904
EFIS: 0423000121
DIST-CO-RTE-PM04-CC-242,680-Var
Award Date06/21/2024
Closeout Date04/14/2025
Work DescriptionINDIVIDUAL SLAB REPLACEMENT, COLD PLANE AC PVMT & PLACE HMA (TYPE A).
Location DescriptionCONTRA COSTA COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 05/06/2024)

Sample Information

Sample Taken Date10/30/2024 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/04/2024
Sample typeQuality Assurance A brief description of the sample1/2"HMA-Type A Mix
The quantity of what the sample constitutes2 Boxes of 1/2"HMA-Type A Mix & 3 Cores From where was the sample collectedSupplier
First name of sampler or witnessed byJacob Last name of sampler or witnessed byVega
Title of samplerLab Technician Telephone number of sampler8316826277
Laboratory sample identificationCon_24_906 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Pleasanton Drier drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-10-30-47
DIME Test ID: 2024-10-30-47-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-11-19

Test Results


Number of tests: 3
Is the sample lab compacted or field compacted?: Field compacted
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 11/05/2024
123

92.6 %

90.6 %

90.0 %

91.1 %

2.3 %
General comments (publicly viewable) (Max 1000 characters): Granite Pleasanton drier drum Plant

Test was verified on 11/19/2024