Summary for Test 2024-10-30-43-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 994191
DEA: 081G8304
EFIS: 0816000079
DIST-CO-RTE-PM08-SBD-40-R100.8/R101.8
Award Date02/07/2023
Closeout Date08/29/2025
Work DescriptionHMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW.
Location DescriptionSAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE
QA Service Level1 (Verified on 03/30/2023)

Sample Information

Sample Taken Date10/30/2024 Sample Unique Key43
Date that the sample was received by the laboratory/organization performing the testing10/31/2024 Sample typeAcceptance
A brief description of the sampleHMA The quantity of what the sample constitutes1 bag
From where was the sample collectedManufacturer First name of sampler or witnessed byQC
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBlue Diamond-Victorville
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0022
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAt the plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number300154-R25 LSM Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-10-30-43
DIME Test ID: 2024-10-30-43-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-11-15

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Kalpesh Patel
Date of test: 10/31/2024
Cumulative Percent Passing
100 %
100 %
100 %
99 %
87 %
72 %
52 %
41 %
31 %
21 %
13 %
7 %
4.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/15/2024 ✔