Summary for Test 2024-11-07-38-1

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 1000276
DEA: 043Y8904
EFIS: 0423000327
DIST-CO-RTE-PM04-NAP-128-29.77-33.45
Award Date04/02/2024
Closeout DateNot set
Work DescriptionSlipout and drainage repairs.
Location DescriptionIn Napa County from 1.8 Mile to 5.6 mile east of Wragg Creek bridge.
QA Service Level1 (Verified on 06/03/2024)

Sample Information

Sample Taken Date11/07/2024 Sample Unique Key38
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/07/2024
Sample typeQuality Assurance A brief description of the sampleClass II AB
The quantity of what the sample constitutesRetaining Wall # 1 From where was the sample collectedJob Site
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byRingler
Title of samplerLab Technician Telephone number of sampler7078161520
Laboratory sample identificationCon_24_938 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Madison Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedSTA. 00+00 to 00+90
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-11-07-38
DIME Test ID: 2024-11-07-38-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2024-11-19

Test Results


Is oversize material: No
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 11/15/2024
In-place wet density: 2.14
Highest adjust wet density: 2.26
% Moisture: 5.9 %
Optimum Moisture: 7.9 %
Relative compaction: 95
General comments (publicly viewable) (Max 1000 characters): Retaining Wall # 1

Test was verified on 11/19/2024