Summary for Test 2024-10-18-59-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 213306
DEA: 07303404
EFIS: 0714000006
DIST-CO-RTE-PM07-VEN-33-0.0/6.3
Award Date06/18/2018
Closeout Date05/10/2021
Work DescriptionCOLD PLANE AC PVMT, PLACE RUBBERIZED AC (TYPE G), AND REPLACE PCC PVMT
Location DescriptionVENTURA COUNTY IN AND NEAR VENTURA FROM ROUTE 33/101 SEPARATION TO 0.1 MILE SOUTH OF PARK VIEW DRIVE
QA Service Level1 (Verified on 12/09/2020)

Sample Information

Sample Taken Date10/18/2024 Sample Unique Key59
Date that the sample was received by the laboratory/organization performing the testing10/21/2024 Sample typeAcceptance
A brief description of the sample4X8 PCC cylinders The quantity of what the sample constitutes130 CY
From where was the sample collectedJob Site First name of sampler or witnessed byDaniel
Last name of sampler or witnessed byMeza Title of samplerAssistant Structure Representative
Telephone number of sampler Laboratory sample identification24-338
Linked DIME Sample ID The fabricator/manufacturer/facility nameNational Ready Mix Concrete Company
Transportation Laboratory (TL) Number24101801 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS72C446T10
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected029753
Concrete batch plantNational Ready Mix Concrete Company The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-18-59
DIME Test ID: 2024-10-18-59-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-11-15

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 11/15/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.03 in
Average diameter of cylinder 2: 4.03 in
Average diameter of cylinder 3: 4.03 in
Maximum load on cylinder 1: 72504 lb
Maximum load on cylinder 2: 76574 lb
Maximum load on cylinder 3: 72926 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.76 in^2
Cross sectional area of cylinder 2: 12.76 in^2
Cross sectional area of cylinder 3: 12.76 in^2
Compressive strength of cylinder 1: 5682.1 psi
Compressive strength of cylinder 2: 6001.1 psi
Compressive strength of cylinder 3: 5715.2 psi
Compressive strength (to nearest 10 psi): 5800 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/15/2024 ✔