Summary for Test 2024-10-17-71-3

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 994378
DEA: 040K6304
EFIS: 0416000111
DIST-CO-RTE-PM04-NAP-29-16.4/19.0
Award Date06/27/2023
Closeout DateNot set
Work DescriptionBRIDGE RAIL REPLACEMENT AND SHOULDER WIDENING.
Location DescriptionNAPA COUNTY NEAR YOUNTVILLE AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF DRY CREEK BRIDGE TO 0.1 MILE NORTH OF CALIFORNIA DRIVE UNDERCROSSIG
QA Service Level1 (Verified on 10/27/2022)

Sample Information

Sample Taken Date10/17/2024 Sample Unique Key71
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing11/13/2024
Sample typeQuality Assurance A brief description of the sampleBarrier NB Perfume
The quantity of what the sample constitutes18 From where was the sample collectedJob Site
First name of sampler or witnessed byAmal Last name of sampler or witnessed byMamlouk
Title of samplerASR Telephone number of sampler9166342698
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameShamrock Materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure namePerfume Creek Bridge Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberD20115EA
The truck number from where the sample was collected2451 The batch plant ticket number from where the sample was collected706786
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-17-71
DIME Test ID: 2024-10-17-71-3
Testing Lab: CT HQ - Vallejo Field Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-11-27

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Nikhil Moon
Date of test: 11/14/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 46032 lb
Maximum load on cylinder 2: 49172 lb
Maximum load on cylinder 3: 43772 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 0.99
Correction factor for cylinder 2: 0.99
Correction factor for cylinder 3: 0.98
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3625.4 psi
Compressive strength of cylinder 2: 3872.7 psi
Compressive strength of cylinder 3: 3412.6 psi
Compressive strength (to nearest 10 psi): 3640 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/27/2024