Summary for Test 2024-10-11-18-7
Test performed: ASTM C39-21Project Information
Project Identifiers | Project ID: 1000409 DEA: 051S1604 EFIS: 0524000176 |
---|---|
DIST-CO-RTE-PM | 05-MON-1-60 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Rocky Creek Slip Out Permanent Restoration Project |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/26/2024) |
Sample Information
Sample Taken Date | 10/11/2024 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/11/2024 |
Sample type | Quality Control | A brief description of the sample | 1 cubic ft. of Concrete for Testing |
The quantity of what the sample constitutes | 1 cubic ft. of Concrete for Testing | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Mark Patrick | Last name of sampler or witnessed by | Baddu |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | ConFab Lathrop | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | VER-95LV |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 11564 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Bed 1A at 2nd truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-10-11-18
DIME Test ID: 2024-10-11-18-7
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-11-14
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Ferdinand Rosal
Date of test: 11/08/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 8.9 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 129493 lb
Maximum load on cylinder 2: 129242 lb
Maximum load on cylinder 3: 130247 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.56 in^2
Cross sectional area of cylinder 2: 12.56 in^2
Cross sectional area of cylinder 3: 12.56 in^2
Compressive strength (to nearest 10 psi): 10320 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/14/2024 ✔