Summary for Test 2013-10-29-10007272-4

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 3958
DEA: 07215914
EFIS: 0700001831
DIST-CO-RTE-PM07-LA-5-1.2/2.1
Award Date12/31/1969
Closeout Date06/14/2016
Work DescriptionWIDEN AND REALIGN FREEWAY AND RECONSTRUCT OVERCROSSING STRUCTURE.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS FROM 0.3 MILE SOUTH OF NORTH FORK COYOTE CREEK BRIDGE TO 0.3 MILE NORTH OF MARQUARDT AVENUE AND AT NORWALK HUB AND LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER
QA Service Level1 (Verified on 05/01/2012)

Sample Information

Sample Taken Date10/29/2013 Sample Unique Key10007272
Date that the sample was received by the laboratory/organization performing the testing11/20/2013 Sample typeAnnual Source Testing
A brief description of the sample1-1/2 PCC Aggregates The quantity of what the sample constitutes5 Bags
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of samplerNot set
Telephone number of samplerNot set Laboratory sample identification3294B
Linked DIME Sample IDNot set The fabricator/manufacturer/facility nameRobertsons - Cabazon
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0008::CABAZON QUARRY
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2013-10-29-10007272
DIME Test ID: 2013-10-29-10007272-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2014-04-07

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Nemencio Daof
Date of test: 12/24/2013
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 8.0 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/7/2014 ✔