Summary for Test 2024-10-25-36-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000037 DEA: 120U2404 EFIS: 1223000058 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-91-R9.8/R18.9 |
| Award Date | 03/12/2024 |
| Closeout Date | 12/15/2025 |
| Work Description | REPLACE CONCRETE SLABS, EXISTING LOOP DETECTORS AND TRAFFIC STRIPING. |
| Location Description | ORANGE COUNTY IN ANAHEIM AND YORBA LINDA FROM 0.3 MILE WEST OF LAKEVIEW AVENUE OVERCROSSING TO RIVERSIDE COUNTY LINE |
| QA Service Level | 1 (Verified on 01/26/2024) |
Sample Information
| Sample Taken Date | 10/25/2024 | Sample Unique Key | 36 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/25/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 RHMAG | The quantity of what the sample constitutes | 3/4 RHMAG |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Jimmy |
| Last name of sampler or witnessed by | Pham | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 24-0978 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AAA Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-10-25-36
DIME Test ID: 2024-10-25-36-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-11-14
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 11/06/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4005.4 g
Mass of the specimen and specimen basket assembly prior to ignition: 6009.3 g
Mass of HMA Sample prior to ignition: 2003.9 g
Mass Loss: 155.7 g
Mass of aggregate remaining after ignition: 1848.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.06 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.71 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 2024AC-SP-0076 | 104.09 KB | 11/13/2024 | 2024-10-25-36-1 | Info |
Test was verified on 11/14/2024 ✔