Summary for Test 2024-10-11-66-12

Test performed: CTM 389-19

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/11/2024 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/16/2024
Sample typeVerification A brief description of the sample3/4" RHMA-G
The quantity of what the sample constitutes24 BOXES RWMA From where was the sample collectedSource
First name of sampler or witnessed byBen Last name of sampler or witnessed bySmith
Title of sampler Telephone number of sampler
Laboratory sample identification1201-JMF Linked DIME Sample ID2024-10-11-67
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeNot Applicable
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number226110 Otay SJR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-10-11-66
DIME Test ID: 2024-10-11-66-12
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-11-13

Test Results


Specified number of passes at 12.7 mm: 10000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 11/13/2024
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >20000
Stripping Inflection Point (Wheel B): >20000
Maximum impression at 5000 passes (left wheel): 4.78 mm
Maximum impression at 5000 passes (right wheel): 2.48 mm
Average impression at 5000 passes (left/right avg): 3.63 mm
Maximum impression at 10000 passes (left wheel): 5.37 mm
Maximum impression at 10000 passes (right wheel): 2.82 mm
Average impression at 10000 passes (left/right avg): 4.09 mm
Maximum impression at 15000 passes (left wheel): 5.87 mm
Maximum impression at 15000 passes (right wheel): 3.03 mm
Average impression at 15000 passes (left/right avg): 4.45 mm
Maximum impression at 20000 passes (left wheel): 6.35 mm
Maximum impression at 20000 passes (right wheel): 4.22 mm
Average impression at 20000 passes (left/right avg): 5.29 mm
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters): Complies

Test was verified on 11/13/2024