Summary for Test 2017-08-28-1-5
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211504 DEA: 060N9904 EFIS: 0612000114 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE,MAD-41U-33.1/33.4,0.0/0.3 |
| Award Date | 10/13/2016 |
| Closeout Date | 10/02/2019 |
| Work Description | BRIDGE SCOUR MITIGATION, SEISMIC RETROFIT AND UPGRADE RAIL. |
| Location Description | FRESNO AND MADERA COUNTIES NEAR FRESNO FROM 0.1 MILE NORTH OF PERRIN ROAD UNDERCROSSING TO 0.1 MILE SOUTH OF AVENUE 9 UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/05/2016) |
Sample Information
| Sample Taken Date | 08/28/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/29/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Welded Hoops |
| The quantity of what the sample constitutes | 12 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | George | Last name of sampler or witnessed by | Lujan |
| Title of sampler | QAI | Telephone number of sampler | 951 640-5331 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Martinez steel | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L36-025-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | PL17101625 |
| Hoop Manufacturer Lot Number(s) | 1, 6, 8 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 7 |
| Diameter of Hoop | 3'-4" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | Martinez Steel | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-08-28-1
DIME Test ID: 2017-08-28-1-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-09-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/30/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 6 | #7/22mm | 0.6 | 53550 | 89250 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/31/2017 ✔