Summary for Test 2024-10-24-65-3

Test performed: CTM 389-19

Project Information

Project IdentifiersProject ID: 1000159
DEA: 033G0504
EFIS: 0323000119
DIST-CO-RTE-PM03-YOL-16-23.5/24.9,25.5/28.9
Award Date05/22/2024
Closeout Date04/02/2025
Work DescriptionPARTIAL DEPTH RECYCLING AND RHMA-G OVERLAY.
Location DescriptionYOLO COUNTY IN AND NEAR ESPARTO FROM ROAD 82B TO 0.3 MILE WEST OF CAPAY CANAL BRIDGE AND FROM 0.3 MILE EAST OF CAPAY CANAL BRIDGE TO 0.3 MILE EAST OF ROAD 86A
QA Service Level1 (Verified on 04/18/2024)

Sample Information

Sample Taken Date10/24/2024 Sample Unique Key65
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/07/2024
Sample typeProduction Start-Up A brief description of the sample6 Boxes
The quantity of what the sample constitutes1/2" RHMA-G From where was the sample collectedSource
First name of sampler or witnessed byJohn Last name of sampler or witnessed byPlant OC
Title of samplerPlant OC Telephone number of sampler
Laboratory sample identificationDaily 24-258 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Woodland Transportation Laboratory (TL) NumberC849958
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-10-24-65
DIME Test ID: 2024-10-24-65-3
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-11-08

Test Results


Specified number of passes at 12.7 mm: 25000
Specimen Preparation Method:
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 11/07/2024
Average impression at 5000 passes (left/right avg): 2.005 mm
Average impression at 10000 passes (left/right avg): 2.32 mm
Average impression at 15000 passes (left/right avg): 2.595 mm
Average impression at 20000 passes (left/right avg): 2.78 mm
Average impression at 25000 passes (left/right avg): 2.94 mm
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/8/2024