Summary for Test 2024-10-11-4-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215620
DEA: 01436404
EFIS: 0100000193
DIST-CO-RTE-PM01-DN-101-35.8/36.5
Award Date07/11/2022
Closeout DateNot set
Work DescriptionDr. Fine Bridge Replacement
Location DescriptionDR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER.
QA Service Level1 (Verified on 03/26/2021)

Sample Information

Sample Taken Date10/11/2024 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing10/14/2024
Sample typeQuality Assurance A brief description of the sampleSR 3/8s CIDH
The quantity of what the sample constitutes38.4 CY From where was the sample collectedJob Site
First name of sampler or witnessed byBarrett Last name of sampler or witnessed byUpdegraff
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2024-10-11-1
The fabricator/manufacturer/facility nameTidewater Smith River Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDr fine bridge Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSR 3/8s CIDH
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected0
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedTRUCK MIXER Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-11-4
DIME Test ID: 2024-10-11-4-2
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-11-08

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Tom Brown
Date of test: 11/08/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 100480 lb
Maximum load on cylinder 2: 89560 lb
Maximum load on cylinder 3: 100310 lb
Type of fracture pattern of cylinder 1: 6
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 7700 psi
General comments (publicly viewable) (Max 1000 characters): 28 Day Break 11/8/24

Test was verified on 11/8/2024