Summary for Test 2024-11-04-26-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 994688
DEA: 070W2904
EFIS: 0721000235
DIST-CO-RTE-PM07-LA-101-1.5/10.9
Award Date06/08/2023
Closeout DateNot set
Work DescriptionDECK METHACRYLATE, JOINT SEAL REPLACEMENT, AC SURFACING, SPALL REPAIR.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/13/2023)

Sample Information

Sample Taken Date11/04/2024 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/06/2024
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed bySAUL Last name of sampler or witnessed byBAHUN
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-11-04-26
DIME Test ID: 2024-11-04-26-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-11-07

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 11/07/2024
Time of test: 07:59 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 64.4 %
Viscosity reading #1 (A) : 0.323 Pa-s
Viscosity reading #2 (B) : 0.321 Pa-s
Viscosity reading #3 (C): 0.323 Pa-s
Average viscosity: 0.322 Pa-s
General comments (publicly viewable) (Max 1000 characters): For informational purposes only

Test was verified on 11/7/2024