Summary for Test 2024-10-09-45-2
Test performed: CTM 521-June 2012Project Information
| Project Identifiers | Project ID: 215620 DEA: 01436404 EFIS: 0100000193 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-101-35.8/36.5 |
| Award Date | 07/11/2022 |
| Closeout Date | Not set |
| Work Description | Dr. Fine Bridge Replacement |
| Location Description | DR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER. |
| QA Service Level | 1 (Verified on 03/26/2021) |
Sample Information
| Sample Taken Date | 10/09/2024 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/09/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Concrete for abutment cidh |
| The quantity of what the sample constitutes | ~11CY of SR 3/8s CIDH | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Barrett | Last name of sampler or witnessed by | Updegraff |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | 2024-10-09 | |
| The fabricator/manufacturer/facility name | Tidewater Contractors | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Dr. Fine Bridge | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SR 3/8s CIDH |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 61515 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | From rebar cage, inside CIDH | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-10-09-45
DIME Test ID: 2024-10-09-45-2
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-11-06
Test Results
Number of specimens: 3
Input Type: Calculated
Tester's full name: Tom Brown
Date of test: 11/06/2024
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): 3
Break Description of Cylinder 2 (if not 'cone'): 5
Break Description of Cylinder 3 (if not 'cone'): 4
Average Compressive Strength (to nearest 10): 6470 lb/in^2
Compressive Strength of Cylinder 1: 76580 lb/in^2
Compressive Strength of Cylinder 2: 86040 lb/in^2
Compressive Strength of Cylinder 3: 82070 lb/in^2
General comments (publicly viewable) (Max 1000 characters): 11/6/24 28 Day Break, 3 Cylinders
Test was verified on 11/6/2024 ✔