Summary for Test 2024-10-11-68-2

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/11/2024 Sample Unique Key68
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/16/2024
Sample typeVerification A brief description of the sampleRWMA Aggregates
The quantity of what the sample constitutes7 bags From where was the sample collectedSource
First name of sampler or witnessed byBen Last name of sampler or witnessed bySmith
Title of sampler Telephone number of sampler
Laboratory sample identification1202-JMF Linked DIME Sample ID2024-10-11-80
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Not Provided
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlnat
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number326122 Otay SJR

Test Details

DIME Sample ID: 2024-10-11-68
DIME Test ID: 2024-10-11-68-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2024-11-06

Test Results


Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 2 Faced and Fine 1 Faced
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 11/05/2024
Mass of fractured, coarse, 2 faced particles tested: 700 g
Mass of questionable, coarse, 2 faced particles tested: 0 g
Mass of unfractured, coarse, 2 faced particles tested: 6 g
Mass of fractured, fine, 1 faced particles tested: 100 g
Mass of questionable, fine, 1 faced particles tested: 0 g
Mass of unfractured, fine, 1 faced particles tested: 0 g
Percentage of questionable, coarse, 2 faced particles tested: 0 %
Percentage of questionable, fine, 1 faced particles tested: 0 %
Percentage of fractured, coarse, 2 faced particles tested: 99 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/6/2024