Summary for Test 2024-10-31-25-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994378
DEA: 040K6304
EFIS: 0416000111
DIST-CO-RTE-PM04-NAP-29-16.4/19.0
Award Date06/27/2023
Closeout DateNot set
Work DescriptionBRIDGE RAIL REPLACEMENT AND SHOULDER WIDENING.
Location DescriptionNAPA COUNTY NEAR YOUNTVILLE AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF DRY CREEK BRIDGE TO 0.1 MILE NORTH OF CALIFORNIA DRIVE UNDERCROSSIG
QA Service Level1 (Verified on 10/27/2022)

Sample Information

Sample Taken Date10/31/2024 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/01/2024
Sample typeProduction Start-Up A brief description of the sampleRAP 25%RAP
The quantity of what the sample constitutes2 Bags of Rap From where was the sample collectedSupplier
First name of sampler or witnessed byNick Last name of sampler or witnessed byHALL
Title of samplerLab Technician Telephone number of sampler7072999133
Laboratory sample identificationCon_24_897 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Vallejo Drier Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceVulcan materials
Aggregate Size Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2024-10-31-25
DIME Test ID: 2024-10-31-25-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-11-12

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 11/01/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1975.8 g
Mass Loss: 131.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 6.50 %
General comments (publicly viewable) (Max 1000 characters): Vulcan Vallejo Drier Drum Plant

Test was verified on 11/12/2024