Summary for Test 2024-11-02-1-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 993387
DEA: 07323404
EFIS: 0716000064
DIST-CO-RTE-PM07-LA-5-R59.5/R67.9
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CULVERT, REPLACE DRAINAGE SYSTEM, RECONST ROADWAY & EMBANKMENT.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM LAKE HUGHES ROAD UNDERCROSSING TO 1.9 MILES NORTH OF TEMPLIN HIGHWAY UNDERCROSSING
QA Service Level1 (Verified on 12/06/2021)

Sample Information

Sample Taken Date11/02/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/02/2024
Sample typeAcceptance A brief description of the sampleWCS PCC Aggregate
The quantity of what the sample constitutes60 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byKevin Last name of sampler or witnessed byHopkins
Title of samplerPlant Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Ready Mix Santa Clarita Transportation Laboratory (TL) NumberC110224C
Inspector Lot Number from the Transportation Laboratory (TL) FormKH117Q Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant numberNational Ready Mix Santa Clarita A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design numberS72C446T10 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-11-02-1
DIME Test ID: 2024-11-02-1-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-11-19

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 11/04/2024
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
516 grams
0.0 grams100 %
11.0 grams98 %
98.0 grams81 %
197.0 grams62 %
317.0 grams39 %
432.0 grams16 %
486.0 grams6 %
500.0 grams3 %
500.0 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/19/2024