Summary for Test 2024-10-31-17-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000009 DEA: 061F8504 EFIS: 0623000103 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-58-27.2/28.2 |
| Award Date | 09/06/2024 |
| Closeout Date | 05/09/2025 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE HMA (TYPE A). |
| Location Description | KERN COUNTY IN BUTTONWILLOW FROM 0.1 MILE WEST OF BUTTONWILLOW DRIVE TO 0.6 MILE WEST OF WASCO WAY |
| QA Service Level | 1 (Verified on 01/08/2024) |
Sample Information
| Sample Taken Date | 10/31/2024 | Sample Unique Key | 17 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/31/2024 |
| Sample type | Acceptance | A brief description of the sample | 3/4 HMA Type A |
| The quantity of what the sample constitutes | L1SL5 10 box HMA, 2 bags of cold feed, | From where was the sample collected | Source |
| First name of sampler or witnessed by | Barrett | Last name of sampler or witnessed by | Felder |
| Title of sampler | Telephone number of sampler | 5599773442 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Griffith Edmonston | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 5 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-10-31-17
DIME Test ID: 2024-10-31-17-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-11-02
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Mike Cozad
Date of test: 11/01/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3909.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 5972.8 g
Mass of HMA Sample prior to ignition: 2063.0 g
Mass Loss: 111.9 g
Mass of aggregate remaining after ignition: 1951.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.44 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.98 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-1F8504_37013__241031_L1SL5_T308 | 83.85 KB | 11/02/2024 | 2024-10-31-17-2 | Info |
Test was verified on 11/2/2024 ✔