Summary for Test 2024-10-29-25-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date10/29/2024 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/30/2024
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-O Mix
The quantity of what the sample constitutes4 Boxes of 1/2"RHMA-O From where was the sample collectedSupplier
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byRingler
Title of samplerLab Technician Telephone number of sampler7078161520
Laboratory sample identificationCon_24_896 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Woodland Batch Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number4
Sublot number5 HMA Mix Number30640542608P
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-10-29-25
DIME Test ID: 2024-10-29-25-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-11-04

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 10/30/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1728.4 g
Mass Loss: 136.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.57 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.17 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.17 %
General comments (publicly viewable) (Max 1000 characters): LOT 4 SUBLOT 5

Test was verified on 11/4/2024