Summary for Test 2017-08-17-7-6
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 209187 DEA: 04235624 EFIS: 0400000678 COOP: 042583 |
|---|---|
| DIST-CO-RTE-PM | 04-SCL,SM-101-52.0/52.6,0.0/0.6 |
| Award Date | 04/28/2015 |
| Closeout Date | 01/08/2020 |
| Work Description | BRIDGE REPLACEMENT |
| Location Description | SANTA CLARA AND SAN MATEO COUNTIES IN PALO ALTO AND EAST PALO ALTO FROM OREGON EXPRESSWAY OVERCROSSING TO 0.3 MILE SOUTH OF UNIVERSITY AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 12/11/2013) |
Sample Information
| Sample Taken Date | 08/17/2017 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/24/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Purple Epoxy Coated HRC 555 End Anchors |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Clement | Last name of sampler or witnessed by | Chan |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | CMC Rebar Fletcher Coating | Transportation Laboratory (TL) Number | C810653 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4067827 | Head Manufacturer Lot Number(s) | 1, 2 |
| Rebar Size | #8 | Headed Bar Model Name | HRC 555 |
| Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
| Head Shape | Circular | Rebar Manufacturer | CMC Rebar |
| Head Manufacturer | CMC HRC | Head Fabricator | CMC Rebar |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2017-08-17-7
DIME Test ID: 2017-08-17-7-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-09-06
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/29/2017
UTM: 400KIP
Temperature: 72 F
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 2 | 0.79 | 75310 | 95330 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/30/2017 ✔