Summary for Test 2024-10-17-54-5
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995524 DEA: 021H3604 EFIS: 0216000040 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-96-76.8/78.0 |
| Award Date | 03/22/2024 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE. |
| Location Description | SISKIYOU COUNTY NEAR HORSE CREEK FROM 0.4 MILE WEST OF KLAMATH RIVER BRIDGE TO 2.0 MILES WEST OF KOHL CREEK |
| QA Service Level | 1 (Verified on 12/27/2023) |
Sample Information
| Sample Taken Date | 10/17/2024 | Sample Unique Key | 54 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/17/2024 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4 Type A HMA |
| The quantity of what the sample constitutes | PSE 16 boxs | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Delgado |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | D79760 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis Inc. - Northstate Asphalt (Redding CA) | Transportation Laboratory (TL) Number | 851392 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-10-17-54
DIME Test ID: 2024-10-17-54-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-10-31
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 10/30/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3034.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 5174.2 g
Mass of HMA Sample prior to ignition: 2139.4 g
Mass Loss: 131.9 g
Mass of aggregate remaining after ignition: 2007.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.79 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.24 %
General comments (publicly viewable) (Max 1000 characters): Pb=5.25%
Test was verified on 10/31/2024 ✔