Summary for Test 2017-08-17-7-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 209187
DEA: 04235624
EFIS: 0400000678
COOP: 042583
DIST-CO-RTE-PM04-SCL,SM-101-52.0/52.6,0.0/0.6
Award Date04/28/2015
Closeout Date01/08/2020
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSANTA CLARA AND SAN MATEO COUNTIES IN PALO ALTO AND EAST PALO ALTO FROM OREGON EXPRESSWAY OVERCROSSING TO 0.3 MILE SOUTH OF UNIVERSITY AVENUE OVERCROSSING
QA Service Level1 (Verified on 12/11/2013)

Sample Information

Sample Taken Date08/17/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/24/2017
Sample typeQuality Assurance A brief description of the samplePurple Epoxy Coated HRC 555 End Anchors
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byClement Last name of sampler or witnessed byChan
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Fletcher Coating Transportation Laboratory (TL) NumberC810653
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4067827 Head Manufacturer Lot Number(s)1, 2
Rebar Size#8 Headed Bar Model NameHRC 555
Size of HeadReduced Size - 4x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerCMC Rebar
Head ManufacturerCMC HRC Head FabricatorCMC Rebar
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2017-08-17-7
DIME Test ID: 2017-08-17-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-09-06

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/29/2017
UTM: 400KIP
Temperature: 72 F
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
110.797557095660Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/30/2017