Summary for Test 2024-09-30-30-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000212 DEA: 112N1944 EFIS: 1123000091 |
|---|---|
| DIST-CO-RTE-PM | 11-IMP-8-R74.5/R83.2 |
| Award Date | 05/31/2024 |
| Closeout Date | 05/06/2025 |
| Work Description | HMA OVERLAY, COLD PLANE, SHOULDER BACKING, STRIPING AND SIGNS. |
| Location Description | IMPERIAL COUNTY ABOUT 26 MILES EAST OF HOLTVILLE FROM 1.0 MILE EAST OF GORDONS WELL OVERCROSSING TO 0.6 MILE WEST OF OGILBY ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 06/11/2024) |
Sample Information
| Sample Taken Date | 09/30/2024 | Sample Unique Key | 30 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/01/2024 |
| Sample type | Quality Assurance | A brief description of the sample | JMFR |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
| Title of sampler | Telephone number of sampler | 6193804522 | |
| Laboratory sample identification | 1101-JMFR | Linked DIME Sample ID | 2024-09-30-32 |
| The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 39 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-09-30-30
DIME Test ID: 2024-09-30-30-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-11-06
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 10/30/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4030.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 5597.3 g
Mass of HMA Sample prior to ignition: 1566.5 g
Mass Loss: 74.4 g
Mass of aggregate remaining after ignition: 1492.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.26 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.49 %
General comments (publicly viewable) (Max 1000 characters): Complies Target 4.45% Tested 4.49%
Test was verified on 11/6/2024 ✔