Summary for Test 2024-05-20-175-4
Test performed: CTM 211-May 2010Project Information
Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 05/20/2024 | Sample Unique Key | 175 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/20/2024 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 3/8" x #8 |
The quantity of what the sample constitutes | Annual Source Testing | From where was the sample collected | Source |
First name of sampler or witnessed by | Jonathan | Last name of sampler or witnessed by | Vasquez |
Title of sampler | QC Supervisor | Telephone number of sampler | (661) 675-5019 |
Laboratory sample identification | Linked DIME Sample ID | 2024-05-20-81 | |
The fabricator/manufacturer/facility name | Cemex Rockfield | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0014 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/8" X #8 | The fabricator/manufacturer designation for the sample | |
The plant number | 4401 | A detailed description of where the material sample was collected | Stockpile @ Plant |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-05-20-175
DIME Test ID: 2024-05-20-175-4
Testing Lab: CEMEX - Central & Southern California
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2024-10-30
Test Results
How many revolutions are required?: 500 Revolution Test
Input Type: Calculated
Tester's full name: Josh Guilmette
Date of test: 05/20/2024
Grading: C
Percent wear: 29 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/30/2024 ✔