Summary for Test 2024-09-13-75-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 212800
DEA: 100G8304
EFIS: 1012000316
DIST-CO-RTE-PM10-MER-152,140,152-Var
Award Date10/31/2023
Closeout DateNot set
Work DescriptionMERCED SEISMIC RESTORATION
Location DescriptionIN MERCED COUNTY ON STATE ROUTES, 59, 140 AND 152 AT VARIOUS BRIDGES.
QA Service Level1 (Verified on 12/20/2018)

Sample Information

Sample Taken Date09/13/2024 Sample Unique Key75
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/13/2024
Sample typeQuality Control A brief description of the sampleconcrete
The quantity of what the sample constitutes100 cy From where was the sample collectedJob Site
First name of sampler or witnessed bySebastian Last name of sampler or witnessed bySeda Ignacio
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameViking Construction Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1922S-FC
The truck number from where the sample was collected295 The batch plant ticket number from where the sample was collected171565
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-09-13-75
DIME Test ID: 2024-09-13-75-5
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-29

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Todd Strait
Date of test: 09/13/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Maximum load on cylinder 1: 130710 lb
Type of fracture pattern of cylinder 1: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 4940 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/29/2024