Summary for Test 2024-09-27-75-3
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994378 DEA: 040K6304 EFIS: 0416000111 |
|---|---|
| DIST-CO-RTE-PM | 04-NAP-29-16.4/19.0 |
| Award Date | 06/27/2023 |
| Closeout Date | Not set |
| Work Description | BRIDGE RAIL REPLACEMENT AND SHOULDER WIDENING. |
| Location Description | NAPA COUNTY NEAR YOUNTVILLE AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF DRY CREEK BRIDGE TO 0.1 MILE NORTH OF CALIFORNIA DRIVE UNDERCROSSIG |
| QA Service Level | 1 (Verified on 10/27/2022) |
Sample Information
| Sample Taken Date | 09/27/2024 | Sample Unique Key | 75 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/27/2024 |
| Sample type | Quality Control | A brief description of the sample | concrete |
| The quantity of what the sample constitutes | 100 cy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Hugo | Last name of sampler or witnessed by | Serrano |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Shamrock Materials | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | D20115EA |
|---|---|---|---|
| The truck number from where the sample was collected | 2436 | The batch plant ticket number from where the sample was collected | 24451 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Concrete Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-09-27-75
DIME Test ID: 2024-09-27-75-3
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-29
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Mathew Lowrance
Date of test: 09/27/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 134020 lb
Maximum load on cylinder 2: 131670 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength (to nearest 10 psi): 4710 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/29/2024 ✔