Summary for Test 2024-10-14-70-1

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 994797
DEA: 040Y2004
EFIS: 0422000256
DIST-CO-RTE-PM04-ALA-580-R7.8/11.0,18.6/21.0
Award Date06/23/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RHMA, AND REPLACE PCC SLABS.
Location DescriptionALAMEDA COUNTY IN AND NEAR LIVERMORE AND PLEASANTON FROM 0.2 MILE EAST OF GREENVILLE OVERHEAD TO 0.3 MILE WEST OF FIRST STREET OVERCROSSING AND FROM 0.2 MILE EAST OF HACIENDA DRIVE OVERCROSSING TO 0.4 MILE EAST OF SAN RAMON ROAD OVERCROSSING
QA Service Level1 (Verified on 08/11/2023)

Sample Information

Sample Taken Date10/14/2024 Sample Unique Key70
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/15/2024
Sample typeQuality Assurance A brief description of the sample1/2"RHMA-G
The quantity of what the sample constitutes750 Tons From where was the sample collectedSource
First name of sampler or witnessed byScott Last name of sampler or witnessed bySowko
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Transportation Laboratory (TL) NumberC031475
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix Number326122
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-10-14-70
DIME Test ID: 2024-10-14-70-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-10-29

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Dennis Yeung
Date of test: 10/18/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7335.6 grams
Mass of oven-dry sample in air for Sample 1: 1522.6 grams
Mass of container filled with the sample and water for Sample 1: 8230.4 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.425
Theoretical maximum density at 25°C (77°F): 2418 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Cores 4A, 4B

Test was verified on 10/29/2024