Summary for Test 2024-10-01-108-3

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 1000037
DEA: 120U2404
EFIS: 1223000058
DIST-CO-RTE-PM12-ORA-91-R9.8/R18.9
Award Date03/12/2024
Closeout DateNot set
Work DescriptionREPLACE CONCRETE SLABS, EXISTING LOOP DETECTORS AND TRAFFIC STRIPING.
Location DescriptionORANGE COUNTY IN ANAHEIM AND YORBA LINDA FROM 0.3 MILE WEST OF LAKEVIEW AVENUE OVERCROSSING TO RIVERSIDE COUNTY LINE
QA Service Level1 (Verified on 01/26/2024)

Sample Information

Sample Taken Date10/01/2024 Sample Unique Key108
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/02/2024
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes10 cy From where was the sample collectedFabricator
First name of sampler or witnessed byRobert Last name of sampler or witnessed byLopez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePro-Cast Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberRRM14062
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedReady Mix Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-01-108
DIME Test ID: 2024-10-01-108-3
Testing Lab: Pro-Cast Products, Incorporated - Highland
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-10-29

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Robert Lopez
Date of test: 10/29/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 219440 lb
Maximum load on cylinder 2: 219770 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 7770 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/29/2024