Summary for Test 2024-10-01-108-3
Test performed: ASTM C39-21Project Information
| Project Identifiers | Project ID: 1000037 DEA: 120U2404 EFIS: 1223000058 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-91-R9.8/R18.9 |
| Award Date | 03/12/2024 |
| Closeout Date | 12/15/2025 |
| Work Description | REPLACE CONCRETE SLABS, EXISTING LOOP DETECTORS AND TRAFFIC STRIPING. |
| Location Description | ORANGE COUNTY IN ANAHEIM AND YORBA LINDA FROM 0.3 MILE WEST OF LAKEVIEW AVENUE OVERCROSSING TO RIVERSIDE COUNTY LINE |
| QA Service Level | 1 (Verified on 01/26/2024) |
Sample Information
| Sample Taken Date | 10/01/2024 | Sample Unique Key | 108 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/02/2024 | Sample type | Quality Control |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 10 cy |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Robert |
| Last name of sampler or witnessed by | Lopez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Pro-Cast Products | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | RRM14062 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 1 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Ready Mix Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-10-01-108
DIME Test ID: 2024-10-01-108-3
Testing Lab: Pro-Cast Products, Incorporated - Highland
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-10-29
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Robert Lopez
Date of test: 10/29/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 219440 lb
Maximum load on cylinder 2: 219770 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 7770 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/29/2024 ✔